Award Abstract # 1937674
NSF/FDA SIR: Morphologically Complex Tissue-Mimicking Phantoms for Evaluating Tissue Scattering Artifacts in Photoacoustic Imaging

NSF Org: DMR
Division Of Materials Research
Recipient: UNIVERSITY OF CALIFORNIA, SAN DIEGO
Initial Amendment Date: November 26, 2019
Latest Amendment Date: November 26, 2019
Award Number: 1937674
Award Instrument: Standard Grant
Program Manager: Abraham Joy
DMR
 Division Of Materials Research
MPS
 Directorate for Mathematical and Physical Sciences
Start Date: December 1, 2019
End Date: November 30, 2022 (Estimated)
Total Intended Award Amount: $200,000.00
Total Awarded Amount to Date: $200,000.00
Funds Obligated to Date: FY 2020 = $200,000.00
History of Investigator:
  • Jesse Jokerst (Principal Investigator)
    jjokerst@ucsd.edu
Recipient Sponsored Research Office: University of California-San Diego
9500 GILMAN DR
LA JOLLA
CA  US  92093-0021
(858)534-4896
Sponsor Congressional District: 50
Primary Place of Performance: University of California-San Diego
9500 Gilman Drive
La Jolla
CA  US  92093-0934
Primary Place of Performance
Congressional District:
50
Unique Entity Identifier (UEI): UYTTZT6G9DT1
Parent UEI:
NSF Program(s): DMR SHORT TERM SUPPORT,
BIOMATERIALS PROGRAM
Primary Program Source: 01002021DB NSF RESEARCH & RELATED ACTIVIT
Program Reference Code(s): 7573
Program Element Code(s): 171200, 762300
Award Agency Code: 4900
Fund Agency Code: 4900
Assistance Listing Number(s): 47.049

ABSTRACT

NON-TECHNICAL ABSTRACT:
Ultrasound is a powerful tool to image diseases including cancer, orthopedic disorders, and heart function. One limitation of ultrasound is that it suffers from low contrast (contrast is the difference in signal intensity between the region of interest and the background tissue). Therefore, there is a large body of research into a special kind of ultrasound known as photoacoustic imaging. Photoacoustic imaging uses light to generate sound only in the area of interest-this increases the contrast. Unfortunately, photoacoustic ultrasound is not yet approved for widespread use in people. This might be partially due to a lack of devices and methods to validate and standardize the novel imaging equipment needed for photoacoustic imaging. Therefore, this work will create specialized plastic objects with known optical and acoustic properties suitable for calibrating and standardizing photoacoustic imaging equipment. This proposal combines expertise from academia and the Food and Drug Administration to identify materials that have optical and acoustic properties similar to human tissue. We will create test objects and methods that will be useful to instrument manufacturers and physicians. The resulting test objects will improve knowledge of how to best create photoacoustic imaging instrumentation and might also streamline regulatory approval of this equipment. In turn, this will increase patient access to this important imaging technique to ultimately advance the national health and quality of life.

TECHNICAL ABSTRACT:
Photoacoustic imaging provides deep tissue imaging similar to ultrasound but with enhanced optical contrast and additional functional and molecular imaging capabilities. However, no standardized performance test methods or phantoms exist for photoacoustic imaging system evaluation unlike mature techniques such as computed tomography. The fundamental limitation-and scientific problem to be studied here is a lack of materials to simultaneously simulate tissue properties over a broad range of optical wavelengths and acoustic frequencies. This leaves investigators, instrument manufacturers, and regulatory agencies without clear strategies to evaluate device safety and effectiveness. This project with the Food and Drug Administration (FDA) builds stable, biologically relevant imaging phantoms with well-characterized optical absorption/scattering coefficients, acoustic impedance, etc. that broadly simulate tissue over a wide range of optical wavelengths and acoustic frequencies. Objective 1 of this research develops phantoms with biologically relevant heterogeneous morphologies and light scattering artifacts during photoacoustic imaging. Phantom material optical and acoustic properties are rigorously characterized using spectrophotometry and acoustic pulse-transmission equipment available at FDA. The imaging phantoms contain multiple layers of background material with different optical and acoustic properties designed to mimic natural tissue (e.g. breast fat and glandular tissue or muscle and fat layers) as well as target inclusions. The inclusions have regular shapes (cylinders, spheres) of varying sizes as well as image-derived, tortuous vessel-mimicking structures. Objective 2 uses these phantoms to establish test methods that evaluate the impact of fluence artifacts on device performance in three different imaging systems. System image uniformity and out-of-plane sensitivity are evaluated during mechanical scanning of probes over realistic vessel-mimicking inclusions known to produce volumetric images. Sets of phantoms containing inclusions mimicking blood absorption at several oxygen saturation levels-but with different background optical properties and layer morphologies-serve in parametric studies of device performance in the face of spectral coloring artifacts. The measurement accuracy of our three photoacoustic imaging systems is quantified to determine device robustness using various fluence correction methods (diffusion theory, Monte Carlo simulations). The outcome is a well-validated tissue-mimicking phantom to support device developers and inform regulatory decision-making including use as a potential Food and Drug Administration Medical Device Development Tool.

This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.

PUBLICATIONS PRODUCED AS A RESULT OF THIS RESEARCH

Note:  When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

Hariri, Ali and Alipour, Kamran and Mantri, Yash and Schulze, Jurgen_P and Jokerst, Jesse_V "Deep learning improves contrast in low-fluence photoacoustic imaging" Biomedical Optics Express , v.11 , 2020 https://doi.org/10.1364/BOE.395683 Citation Details
Hariri, Ali and Palma-Chavez, Jorge and Wear, Keith A. and Pfefer, T. Joshua and Jokerst, Jesse V. and Vogt, William C. "Polyacrylamide hydrogel phantoms for performance evaluation of multispectral photoacoustic imaging systems" Photoacoustics , v.22 , 2021 https://doi.org/10.1016/j.pacs.2021.100245 Citation Details
Palma-Chavez, Jorge and Pfefer, T. Joshua and Agrawal, Anant and Jokerst, Jesse V. and Vogt, William C. "Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment" Journal of Biomedical Optics , v.26 , 2021 https://doi.org/10.1117/1.JBO.26.9.090901 Citation Details
Palma-Chavez, Jorge and Wear, Keith A. and Mantri, Yash and Jokerst, Jesse V. and Vogt, William C. "Photoacoustic imaging phantoms for assessment of object detectability and boundary buildup artifacts" Photoacoustics , v.26 , 2022 https://doi.org/10.1016/j.pacs.2022.100348 Citation Details
Yim, Wonjun and Borum, Raina M. and Zhou, Jiajing and Mantri, Yash and Wu, Zhuohong and Zhou, Jingcheng and Jin, Zhicheng and Creyer, Matthew and Jokerst, Jesse V. "Ultrasmall gold nanorod-polydopamine hybrids for enhanced photoacoustic imaging and photothermal therapy in second near-infrared window" Nanotheranostics , v.6 , 2022 https://doi.org/10.7150/ntno.63634 Citation Details
Yim, Wonjun and Zhou, Jiajing and Mantri, Yash and Creyer, Matthew N. and Moore, Colman A. and Jokerst, Jesse V. "Gold NanorodMelanin Hybrids for Enhanced and Prolonged Photoacoustic Imaging in the Near-Infrared-II Window" ACS Applied Materials & Interfaces , v.13 , 2021 https://doi.org/10.1021/acsami.1c00993 Citation Details
Yim, Wonjun and Zhou, Jiajing and Sasi, Lekshmi and Zhao, Jiayu and Yeung, Justin and Cheng, Yong and Jin, Zhicheng and Johnson, Wade and Xu, Ming and PalmaChavez, Jorge and Fu, Lei and Qi, Baiyan and Retout, Maurice and Shah, Nisarg J. and Bae, Jinhye a "3DBioprinted Phantom with Human Skin Phototypes for Biomedical Optics" Advanced Materials , v.35 , 2022 https://doi.org/10.1002/adma.202206385 Citation Details

PROJECT OUTCOMES REPORT

Disclaimer

This Project Outcomes Report for the General Public is displayed verbatim as submitted by the Principal Investigator (PI) for this award. Any opinions, findings, and conclusions or recommendations expressed in this Report are those of the PI and do not necessarily reflect the views of the National Science Foundation; NSF has not approved or endorsed its content.

Photoacoustic imaging is a special type of ultrasound but that offers more information about body function and the molecules present in the body. It is a “light-in/sound-out” technique unlike regular ultrasound which is "sound-in/sound-out" (echo). It is important to characterize photoacoustic imaging to make sure it is safe and effective. One way that people ensure imaging techniques are safe and effective is with materials that mimic human tissue, i.e., pieces of plastic called “phantoms.” Phantoms have value because they are cheaper and more controlled than using real humans for testing. However, no phantoms exist for photoacoustic imaging systems evaluation unlike mature techniques such as computed tomography. It is particularly difficult to make phantoms for photoacoustic imaging because the material must replicate both the optical and acoustic properties of human tissue. The lack of phantoms leaves investigators, instrument manufacturers, and regulatory agencies without clear strategies to evaluate photoacoustic device safety and effectiveness. This project with the Food and Drug Administration (FDA) built stable, biologically relevant imaging phantoms with well-characterized optical absorption/scattering coefficients, acoustic impedance, etc. that broadly simulate tissue over a wide range of optical wavelengths and acoustic frequencies. We first created materials with biologically relevant morphologies and light scattering features during photoacoustic imaging. Phantom material optical and acoustic properties were rigorously characterized using spectrophotometry and acoustic pulse-transmission experiments. The inclusions had regular shapes (cylinders, spheres) of varying sizes. System image uniformity and out-of-plane sensitivity were evaluated during mechanical scanning. Phantoms containing inclusions mimicking blood absorption at different oxygen saturation levels offered parametric studies of device performance in the face of spectral coloring artifacts. The measurement accuracy of three photoacoustic imaging systems was quantified to determine device robustness. The outcome is a well-validated tissue-mimicking phantom design to support device developers and inform regulatory decision-making including use as a potential Food and Drug Administration Medical Device Development Tool.